Maintenance and Testing of a Diesel Generator -How?

The maintenance and testing of diesel generators is crucial, requiring a regular service program and written records. Key checks include: 1. Cooling System - Radiator, coolant, hoses, fan, etc. 2. Fuel System - Fuel tank, filters, lines, etc. 3. Lubrication Oil System - Oil, filters, pressure. 4. Starting System - Batteries, motor, controls. 5. Generator - Bearings, slip rings, etc. 6. Control Panel - Manual/auto controls, meter readings. 7. Gas Engine - Gas lines, ignition system. 8. Insulation Test - Stator and rotor checks. 9. Load Testing - Conduct full load tests. After checks, maintain records for sharing. Videos related to generator service and maintenance are available.

The maintenance and testing of a diesel generator is very important. You must have a regular service program together with written records. These prove what did and what did not happen.

Every Diesel generator service and maintenance regime includes tests and checks of the following:

Line interactive do have a micro break in power whereas a Double conversion have NO BREAK. Double Conversion Uninterruptible power supply ( UPS) systems are better to protect IT loads. All UPS systems synchronise the output frequency with the input by means of built in Automatic voltage regulators (AVRs).

  • Cooling system.
  • Radiator / heat exchanger, coolant, hoses and connections, fan drive pulley and fan, fan belts, jacket water heater, water pump, thermostats.
  • Fuel system.
  • Fuel tank, water trap/separator, fuel lines and connections, governor and controls, fuel filters – primary/secondary, fuel pressure, air induction and exhaust system, air filter, air filter service indicator, air inlet system, turbocharger, exhaust manifold, valves and valve rotators.
  • Lubrication oil system.
  • Oil, oil filters, oil pressure, crankcase breather.
  • Starting system.
  • Batteries, battery specific gravity, battery charger, starting motor, alternator, engine monitor and safety controls, gauges, remote annunciators/alarms.
  • Generator.
  • Bearings, slip rings and brushes, space heaters, vibration isolators.
  • Control panel.
  • Start controls – manual/auto, voltmeter, ammeter, frequency meter, circuit breaker, auto transfer switch.
  • Gas engine.
  • Gas lines and connections, carburettor and linkage, magneto/distributor, ignition system, spark plugs.
  • Insulation test.
  • Main stator, main rotor, exciter stator, exciter rotor.
  • Load testing – with full load, perform a two to four hour load test.

Now you have carried out al these checks, record them, in as much as hard copies and digital copies to share with your colleagues.

Generator Service and Maintenance Checks Power Continuity from Power Continuity Ltd on Vimeo

video thumbnail

Playing in picture-in-picture

Play

Settings

QualityAuto

Picture-in-Picture

power continuity diesel generator maintenance remove debris and dust

power continuity diesel generator maintenance checks

power continuity maintenance checks on diesel generator

If you want to Service your Diesel Generator Call us on 0845 055 8455 We’re here to help!